PDF | 10.1MB
Cemintel Smooth Plank provides a flexible, external cladding option. It is ideally used as a complete external cladding system, or for second storey additions.
Planks are available in two widths and can be painted, or stained, to create the desired finish. The look is completed with a strong shadow line from the plank overlap. These planks provide for fast coverage, as they can be nailed directly to the frame, providing a drained cavity solution.
Features
- Provides a flexible, external cladding option
- Ideally used as a complete external cladding system, or for second storey additions
- Planks available in two widths and can be painted, or stained, to create the desired finish
- Strong shadow line from the plank overlap
- Fast coverage, as planks can be nailed directly to the frame, providing a drained cavity solution
Downloads
Associated files for this Cemintel product are available for download.
Plank and Cladding Product Flyer
Smooth Plank BIM files
ZIP | 976.5KB
Weatherboard and Plank Design & Installation Guide
PDF | 15.9MB
Cemintel Façades & Cladding Design Guide
PDF | 5.1MB
Cemintel 19mm Trims
PDF | 1.2MB
Plank Product Warranty
PDF | 104.6KB
Fire Performance Guide - Fibre Cement Cladding
PDF | 3.3MB
Cemintel Product Portfolio
PDF | 19.7MB
Cemintel Fibre Cement Safety Data Sheet
PDF | 466.7KB
Cemintel Trim Warranty
PDF | 64.4KB
Trims Product Flyer
PDF | 1.5MB
Technical Data
APPLICATIONS
Result | |
---|---|
Applications | Façades & Cladding |
Type of Building Structure | Residential Housing Buildings within the scope of AS4055 |
Wet Areas | No |
PANEL - DIMENSIONAL & GEOMETRICAL CHARACTERISTICS
Dimensional/Geometrical Characteristic | Specification | Manufacturing Tolerance | Relevant Standard |
---|---|---|---|
Panel Dimensions | 230mmW x 4200mmL x 7.5mmD 300mmW x 4200mmL x 7.5mmD |
Width +3 -3 mm Length +0 -3 mm Thickness +0.5 -0 mm |
|
Profile | Square Edge | ||
Perpendicularity/squareness of edges | 2mm/linear meter | ||
Weight (typical) | 12.2kg/m2 | ||
Layout Options | Horizontal | ||
Jointing | Concealed |
PANEL - STRENGTH & MOISTURE RELATED PROPERTIES
Physical Property | Result | Relevant Standard |
---|---|---|
Modulus of Rupture (Wet) | > 9 MPa | AS2908.2 |
Modulus of Elasticity (Wet) | 3-5 GPa | AS2908.2 |
Density (Oven Dry) | 1350 kg/m3 | AS2908.2 |
Water Vapor Diffusion | Not Required | Not Required |
Water Tightness (24hrs) | No water droplet | AS2908.2 |
Water Absorption (Saturated – 48hrs) | 30 wt% | ASTM C 1186 |
Moisture Content (EMC) | 7 wt% | ASTM C 1186 |
Moisture Movement | 0.062% | ASTM C 1186 |
PANEL - OTHER DURABILITY/WEATHER RESISTANCE INDICATORS
Test | Result | Relevant Standard |
---|---|---|
Heat Rain | PASSED (25 Cycles) | AS2908.2 |
Freeze Thaw | PASSED (50 Cycles) | AS2908.2 |
Warm Water Resistance | PASSED (56 days) | AS2908.2 |
Soak Dry | PASSED (25 Cycles) | AS2908.2 |
PANEL - FINISH CHARACTERISTICS
Characteristic | Result | Relevant Standard |
---|---|---|
Finish | Unprimed | |
Coating Type | ||
Colour Bodied | No | |
Paint Type | ||
UV Resistance | N/A | N/A |
Formaldehyde Emission Rate | N/A | N/A |
VOC Emission Rate | N/A | N/A |
Spectral Reflectivity Values | Solar Reflectance % | Solar Absorption % | Basix Colour | Relevant Standard |
---|---|---|---|---|
Smooth Plank | N/A |
PANEL - FIRE RESISTANCE, THERMAL & ACCOUSTIC PROPERTIES
Characteristic | Result | Relevant Standard |
---|---|---|
FIRE RESISTANCE | ||
Combustibility | Suitable for use in applications where non-combustible materials are specified by the Deemed to Satisfy Provisions of the 2016 BCA Vol 1 Amendment 1 Clause C1.9 (2015 BCA Vol Clause C1.12) | |
Fire Hazard Properties | Group 1 Av Specific Extinction Area <250 | AS 5637.1 |
Classification | 1 | AS/NZ 3837 |
THERMAL CONDUCTIVITY | ||
Thermal Conductivity (λ-Factor) | ≈ 0.2704 W/m.K | |
Thermal Expansion Co-efficient | 0.005-0.01mm/mK | N/A |
ACOUSTIC VALUE | ||
Sound reduction (depends on construction) | N/A | N/A |
SYSTEM SOLUTIONS
Characteristic | Result | Relevant Standard |
---|---|---|
Within Scope of AS4055? | Yes | |
Wind Loading - Residential housing buildings within the scope of AS4055 | N1, N2, N3, N4, C1, C2 | |
Weatherproofing | Suitable for all building classes set out in the BCA (ie 1&10, 2-9) | N/A |
Cyclonic Conditions | N/A | N/A |
Fire Resistance Limits (FRLs) | Up to 90/90/90 | Refer to Gyprock® The Red Book™ |
Bushfire Construction | BAL 29 (Construction for Bushfire Attack Level 29 for an external wall) | AS 3959-8 |
Acoustic | Acoustic solutions of up to RW/RW+CTR 50/42 are detailed | Refer to Gyprock® The Red Book™ |
Thermal | Thermal solutions of up to RT(sum)/RT(win) 3.4/3.8 are detailed | Refer to Gyprock® The Red Book™ |
FIXING
Characteristic | |
---|---|
Maximum Span (Stud Spacing) | Up to 600mm |
DIRECT FIX | |
Nail to Timber Frame | Yes |
Screw to Timber Frame | No |
Screw to Steel Frame | Yes |
CAVITY FIX | |
Timber Frame | Yes |
Steel Frame | Yes |
Masonry Frame | No |
EXPOSED FASTENERS | |
Screw | No |
Rivet | No |
Nail | No |
CONCEALED FASTENERS | |
Clip | Yes |
Countersunk Screw/Nail | No |
Adhesive, Split Batten, etc. | No |
Hidden by Overlapping Panel | No |
Flush Jointed (Taped) | No |
WARRANTY 25 Years
Other Recommended Products
You may also be interested in these Cemintel products to work with, complement, or as an alternative to the product you are currently viewing.