Cemintel Cladding provides a lightweight panel solution in a most simple and traditional form.
Panels are manufactured utilising a full steels process and are clean and smooth, providing a better painted finish. The panels are very easy to install with traditional nail-on-frame methods, as well as an option for a drained cavity cladding solution. Available in a range of sizes that make it versatile in application with minimal waste.
Features
- Lightweight panel solution in a simple and traditional form
- Manufactured utilising a full steels process
- Clean and smooth, providing a better painted finish
- Easy to install with traditional nail-on-frame methods, as well as a drained cavity cladding option
- Range of sizes make it versatile in application with minimal waste
Downloads
Associated files for this Cemintel product are available for download.
Plank and Cladding Product Flyer
Cladding Sheet BIM files
ZIP | 924.0KB
Cemintel Façades & Cladding Design Guide
PDF | 5.1MB
Fire Performance Guide - Fibre Cement Cladding
PDF | 3.3MB
Cemintel Product Portfolio
PDF | 19.7MB
Rigid Air Barrier Installation Guide
PDF | 4.6MB
Cemintel Fibre Cement Safety Data Sheet
PDF | 466.7KB
Technical Data
APPLICATIONS
Result | |
---|---|
Applications | Façades & Cladding, Eaves & Soffits |
Type of Building Structure | Residential Housing Buildings within the scope of AS4055 |
Wet Areas | No |
PANEL - DIMENSIONAL & GEOMETRICAL CHARACTERISTICS
Dimensional/Geometrical Characteristic | Specification | Manufacturing Tolerance | Relevant Standard |
---|---|---|---|
Panel Dimensions | 900mmW x 2400mmL x 6mmD 1200mmW x 1800mmL x 6mmD 1200mmW x 2400mmL x 6mmD 1200mm W x 2700mmL x 6mmD 1200mm W x 3000mmL x 6mmD 900mmW x 1800mmL x 4.5mmD 900mmW x 2400mmL x 4.5mmD 1200mmW x 1800mmL x 4.5mmD 1200mmW x 2400mmL x 4.5mmD 1200mmW x 2700mmL x 4.5mmD 1200mmW x 3000mmL x 4.5mmD |
Width +0 -3 mm Length +0 -4 mm Thickness +0.5 -0 mm |
|
Profile | Square Edge | ||
Perpendicularity/squareness of edges | 2mm/linear meter | ||
Weight (typical) | 6mm = 10kg/m2, 4.5mm = 7.3kg/m2 | ||
Layout Options | Vertical | ||
Jointing | Cover Strip |
PANEL - STRENGTH & MOISTURE RELATED PROPERTIES
Physical Property | Result | Relevant Standard |
---|---|---|
Modulus of Rupture (Wet) | > 9 MPa | AS2908.2 |
Modulus of Elasticity (Wet) | 3-5 GPa | AS2908.2 |
Density (Oven Dry) | 1350 kg/m3 | AS2908.2 |
Water Vapor Diffusion | Not Required | Not Required |
Water Tightness (24hrs) | No water droplet | AS2908.2 |
Water Absorption (Saturated – 48hrs) | 30 wt% | ASTM C 1186 |
Moisture Content (EMC) | 7 Wt % | ASTM C 1186 |
Moisture Movement | 0.06% | ASTM C 1186 |
PANEL - OTHER DURABILITY/WEATHER RESISTANCE INDICATORS
Test | Result | Relevant Standard |
---|---|---|
Heat Rain | PASSED (25 Cycles) | AS2908.2 |
Freeze Thaw | PASSED (50 Cycles) | AS2908.2 |
Warm Water Resistance | PASSED (56 days) | AS2908.2 |
Soak Dry | PASSED (25 Cycles) | AS2908.2 |
PANEL - FINISH CHARACTERISTICS
Characteristic | Result | Relevant Standard |
---|---|---|
Finish | Unprimed | |
Coating Type | ||
Colour Bodied | No | |
Paint Type | ||
UV Resistance | N/A | N/A |
Formaldehyde Emission Rate | N/A | N/A |
VOC Emission Rate | N/A | N/A |
Spectral Reflectivity Values | Solar Reflectance % | Solar Absorption % | Basix Colour | Relevant Standard |
---|---|---|---|---|
Cladding Sheet | N/A |
PANEL - FIRE RESISTANCE, THERMAL & ACCOUSTIC PROPERTIES
Characteristic | Result | Relevant Standard |
---|---|---|
FIRE RESISTANCE | ||
Combustibility | Suitable for use in applications where non-combustible materials are specified by the Deemed to Satisfy Provisions of the 2016 BCA Vol 1 Amendment 1 Clause C1.9 (2015 BCA Vol Clause C1.12) | |
Fire Hazard Properties | Group 1 Av Specific Extinction Area <250 | AS 5637.1 |
Classification | 1 | AS/NZ 3837 |
THERMAL CONDUCTIVITY | ||
Thermal Conductivity (λ-Factor) | ≈ 0.2704 W/m.K. | |
Thermal Expansion Co-efficient | 0.005-0.01mm/mK | N/A |
ACOUSTIC VALUE | ||
Sound reduction (depends on construction) | N/A | N/A |
SYSTEM SOLUTIONS
Characteristic | Result | Relevant Standard |
---|---|---|
Within Scope of AS4055? | Yes | |
Wind Loading - Residential housing buildings within the scope of AS4055 | N1, N2, N3, C1, C2, C3 | |
Weatherproofing | Suitable for all building classes as set out in the BCA (ie 1&10, 2-9) | N/A |
Cyclonic Conditions | N/A | N/A |
Fire Resistance Limits (FRLs) | Up to 120/120/120 - 180/180 | Refer to Gyprock® The Red Book™ |
Bushfire Construction | BAL 29 (Construction for Bushfire Attack Level 29 for an external wall), BAL 40 (Eaves only) - 6mm cladding sheet only | AS 3959-8 |
Acoustic | Acoustic solution of up to RW/RW+CTR 53/44 are detailed | Refer to Gyprock® The Red Book™ |
Thermal | Thermal solutions of up to RT(sum)/RT(win) 3.5/3.8 are detailed | Refer to Gyprock® The Red Book™ |
FIXING
Characteristic | |
---|---|
Maximum Span (Stud Spacing) | Up to 600mm |
DIRECT FIX | |
Nail to Timber Frame | Yes |
Screw to Timber Frame | Option for ceilings/eaves |
Screw to Steel Frame | No |
CAVITY FIX | |
Timber Frame | Yes |
Steel Frame | Yes |
Masonry Frame | No |
EXPOSED FASTENERS | |
Screw | No |
Rivet | No |
Nail | No |
CONCEALED FASTENERS | |
Clip | No |
Countersunk Screw/Nail | Yes |
Adhesive, Split Batten, etc. | No |
Hidden by Overlapping Panel | No |
Flush Jointed (Taped) | No |